Sign in

+34 91 380 33 18

LABORATORY EXTRACTORS


Laboratory extraction apparatus for separation and purification

Laboratory extraction apparatus is used in analytical chemistry, quality control and scientific research to separate compounds of interest from complex sample matrices. These systems allow substances to be extracted under controlled conditions, helping to improve solvent efficiency and the reproducibility of analytical procedures.

Extraction equipment is commonly used in pharmaceutical, food, environmental and chemical laboratories where reliable sample preparation and consistent analytical results are essential.

Pobel offers both complete extraction apparatus and extractor accessories for different laboratory requirements.

What is laboratory extraction apparatus used for?

Laboratory extraction systems are primarily used to isolate compounds from solid or liquid samples so that they can be analysed, purified or used in subsequent procedures.

Depending on the extraction technique, they can be used to obtain concentrated extracts, recover soluble compounds or prepare samples for qualitative and quantitative analysis.

One of the most established techniques is solid-liquid extraction, in which a suitable solvent selectively dissolves compounds from a solid sample. Continuous extraction systems make it possible to expose the sample repeatedly to solvent without requiring constant manual intervention.

How does a Soxhlet extraction system work?

The Soxhlet extraction apparatus is one of the best-known systems for continuous solid-liquid extraction. Its operation is based on repeated cycles of solvent evaporation, condensation and siphoning.

The process generally follows these stages:

  • Solvent heating: the solvent is heated in a flask until it evaporates.
  • Vapour condensation: the solvent vapour rises through the apparatus and reaches a condenser, where it cools and returns to the liquid state.
  • Sample extraction: the condensed solvent comes into contact with the solid sample and dissolves the compounds of interest.
  • Siphoning: when the extraction chamber reaches the required level, the solvent containing the extracted compounds returns to the boiling flask.
  • Continuous cycling: the process is repeated automatically, exposing the sample to successive portions of solvent.

This continuous cycle makes Soxhlet extraction particularly useful when the target compounds have limited solubility in the selected solvent and repeated contact between the solvent and sample is beneficial.

Main components of an extraction apparatus

A complete laboratory extraction system combines several pieces of glassware that must work together correctly.

Extraction body

The extractor body contains the sample during the extraction process. In a Soxhlet system, it incorporates the siphon mechanism that periodically returns the solvent and extracted compounds to the boiling flask.

Boiling flask

The flask contains the extraction solvent and receives the extracted compounds as the cycles progress. It is heated to generate the solvent vapour required for continuous operation.

Laboratory condenser

A laboratory condenser cools the solvent vapour and converts it back into liquid before it reaches the sample.

Efficient condensation is important because it allows the solvent to remain within the extraction cycle and reduces unnecessary solvent loss.

Extraction thimble or sample holder

The solid sample is usually placed inside a suitable extraction thimble or porous container. This allows the solvent to pass through the sample while helping retain solid particles inside the extraction chamber.

Borosilicate glass extraction apparatus

Pobel extraction apparatus is manufactured from borosilicate glass 3.3, a material widely used in laboratory glassware because of its chemical resistance and low coefficient of thermal expansion.

These properties are particularly important in extraction systems because the glassware is repeatedly exposed to heated solvent, hot vapour and cooling during the condensation stage.

Ground-glass joints also allow the different components of the apparatus to be assembled securely while maintaining the vapour path required for correct operation.

Applications of laboratory extraction systems

Laboratory extraction apparatus is used in a wide range of analytical and research applications.

Food and fat analysis

Soxhlet extraction has traditionally been used to extract fats and oils from solid food samples. The extracted material can subsequently be quantified or subjected to further analysis depending on the analytical method.

Environmental analysis

Extraction systems can be used during the preparation of soil, sediment and other environmental samples to recover compounds that need to be identified or quantified.

Pharmaceutical and chemical laboratories

Laboratory extraction can form part of the isolation, purification and analytical control of organic compounds, active substances and other chemical materials.

Research and method development

Controlled extraction systems are also useful when developing analytical methods and studying the behaviour of different compounds, solvents and sample matrices.

How to choose laboratory extraction apparatus

The most suitable extraction system depends on the sample, solvent and analytical method being used. Before selecting equipment, consider:

  • the type of sample and compound to be extracted;
  • the required extractor capacity;
  • the volume and type of solvent;
  • the required flask capacity;
  • the type and size of the ground-glass joints;
  • the condenser required for the system;
  • the size of the extraction thimble or sample holder;
  • and whether a complete apparatus or individual replacement components are required.

Pobel offers complete Soxhlet extraction apparatus in different capacities, as well as accessories and replacement components for extraction systems.

Maintenance and safe use

Correct cleaning and inspection are essential for reliable laboratory extraction and for maintaining the condition of the glassware.

  • Clean the extractor body, flask and condenser thoroughly after use to prevent cross-contamination.
  • Inspect glass components and ground joints for cracks, chips or other damage before assembling the system.
  • Ensure all components and joints are correctly supported and connected.
  • Use heating equipment appropriate for the flask and solvent being used.
  • Check that cooling water is circulating correctly through the condenser.
  • Follow the laboratory's safety procedures when working with volatile, flammable or hazardous solvents.

Extraction processes involving volatile solvent vapours should be carried out under appropriate laboratory ventilation or fume extraction according to the hazards of the substances being used.

Laboratory extraction apparatus from Pobel

Pobel supplies laboratory extraction apparatus for continuous solid-liquid extraction, including complete Soxhlet systems and the individual components required to configure, maintain or repair extraction assemblies.

The range includes complete systems in different capacities together with extractor bodies, covers and other accessories manufactured for professional laboratory use. Pobel's complete Soxhlet sets combine the extractor body, condenser and flask required for continuous extraction.

If you need help choosing the appropriate extraction system, capacity or components for your analytical method, contact us for technical advice.

Product added to wishlist
Product added to compare.